14 resultados para epidural space

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BackgroundThe success of epidural anaesthesia depends on correct identification of the epidural space. For several decades, the decision of whether to use air or physiological saline during the loss of resistance technique for identification of the epidural space has been governed by the personal experience of the anaesthesiologist. Epidural block remains one of the main regional anaesthesia techniques. It is used for surgical anaesthesia, obstetrical analgesia, postoperative analgesia and treatment of chronic pain and as a complement to general anaesthesia. The sensation felt by the anaesthesiologist from the syringe plunger with loss of resistance is different when air is compared with saline (fluid). Frequently fluid allows a rapid change from resistance to non-resistance and increased movement of the plunger. However, the ideal technique for identification of the epidural space remains unclear.ObjectivesTo evaluate the efficacy and safety of both air and saline in the loss of resistance technique for identification of the epidural space.To evaluate complications related to the air or saline injected.Search methodsWe searched the Cochrane Central Register of Controlled Trials (CENTRAL) (2013, Issue 9), MEDLINE, EMBASE and the Latin American and Caribbean Health Science Information Database (LILACS) (from inception to September 2013). We applied no language restrictions. The date of the most recent search was 7 September 2013.Selection criteriaWe included randomized controlled trials (RCTs) and quasi-randomized controlled trials (quasi-RCTs) on air and saline in the loss of resistance technique for identification of the epidural space.Data collection and analysisTwo review authors independently assessed trial quality and extracted data.Main resultsWe included in the review seven studies with a total of 852 participants. The methodological quality of the included studies was generally ranked as showing low risk of bias inmost domains, with the exception of one study, which did not mask participants. We were able to include data from 838 participants in the meta-analysis. We found no statistically significant differences between participants receiving air and those given saline in any of the outcomes evaluated: inability to locate the epidural space (three trials, 619 participants) (risk ratio (RR) 0.88, 95% confidence interval (CI) 0.33 to 2.31, low-quality evidence); accidental intravascular catheter placement (two trials, 223 participants) (RR 0.90, 95% CI 0.33 to 2.45, low-quality evidence); accidental subarachnoid catheter placement (four trials, 682 participants) (RR 2.95, 95% CI 0.12 to 71.90, low-quality evidence); combined spinal epidural failure (two trials, 400 participants) (RR 0.98, 95% CI 0.44 to 2.18, low-quality evidence); unblocked segments (five studies, 423 participants) (RR 1.66, 95% CI 0.72 to 3.85); and pain measured by VAS (two studies, 395 participants) (mean difference (MD) -0.09, 95% CI -0.37 to 0.18). With regard to adverse effects, we found no statistically significant differences between participants receiving air and those given saline in the occurrence of paraesthesias (three trials, 572 participants) (RR 0.89, 95% CI 0.69 to 1.15); difficulty in advancing the catheter (two trials, 227 participants) (RR 0.91, 95% CI 0.32 to 2.56); catheter replacement (two trials, 501 participants) (RR 0.69, 95% CI 0.26 to 1.83); and postdural puncture headache (one trial, 110 participants) (RR 0.83, 95% CI 0.12 to 5.71).Authors' conclusionsLow-quality evidence shows that results do not differ between air and saline in terms of the loss of resistance technique for identification of the epidural space and reduction of complications. Applicability might be compromised, as most of the results described in this review were obtained from parturient patients. This review underlines the need to conduct well-designed trials in this field.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Buprenorphine plasma concentrations were measured after administering buprenorphine (20 mu g/kg) into the lumbosacral epidural space of conscious cats chronically instrumented with an epidural catheter. Blood was collected from a jugular vein before injection and 15, 30, 45 and 60 min and 2, 3, 4, 5, 6, 8, 12 and 24 h after administration. Plasma buprenorphine concentrations were measured using ELISA. Background concentration (before injection) was 1.27 +/- 0.27 ng/mL (mean +/- SD). Including background concentration, the mean peak plasma concentration was obtained 15 min after injection (5.82 +/- 3.75 ng/mL), and ranged from 3.79 to 2.20 ng/mL (30 min-3 h), remaining between 1.93 and 1.77 ng/mL (412 h), and declined to 1.40 +/- 0.62 ng/mL at 24 h. Elimination half-life was 58.8 +/- 40.2 min and clearance 56.7 +/- 21.5 mL/min. Results indicate early rapid systemic uptake of buprenorphine from epidural administration with plasma concentrations similar to using buccal or IM routes by 15 min postinjection. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Foram realizados estudos empregando-se analgésicos por via epidural e subcutânea em cadelas de diferentes raças e idades, submetidas à castração mediante celiotomia. Vinte animais foram tranquilizados e anestesiados com tiletamina-zolazepam, e aleatoriamente distribuídos em quatro grupos (n=5), de acordo com o fármaco e a via de administração. Os do grupo morfina (GM) foram submetidos à anestesia epidural no espaço lombossacro, com morfina (0,1mg/kg) associada ao cloreto de sódio a 0,9%. Aos do grupo xilazina (GX), foram administrados xilazina (0,2mg/kg) e cloreto de sódio a 0,9%. Os do grupo meloxicam (GME) receberam 0,2mg/kg do anti-inflamatório meloxicam associado ao cloreto de sódio a 0,9%, injetado pela via subcutânea. Os do grupo-controle (CG) receberam apenas cloreto de sódio a 0,9%. O volume final para as injeções epidurais foi padronizado para 0,3mL/kg. A mensuração inicial da concentração de cortisol plasmático, do ritmo cardíaco, da frequência respiratória e os parâmetros comportamentais foram registrados imediatamente antes do procedimento cirúrgico (M1). Registros adicionais foram apresentados às 2, 6, 12 e 24 horas após o procedimento cirúrgico (M2, M3, M4 e M5, respectivamente). As variáveis comportamentais foram avaliadas por meio de sinais clínicos e seus respectivos escores. em GX foram observadas depressão respiratória, bradicardia e concentração de cortisol mais alta do que o registrado no GM. A analgesia obtida pelo meloxicam foi considerada ineficiente. É possível concluir que a morfina, via epidural, promoveu menor incidência de efeitos colaterais e melhor analgesia e bem-estar animal.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: Não existem estudos que relatem as repercussões renais determinadas pela injeção de doses elevadas de clonidina no espaço peridural. O objetivo do estudo foi avaliar os efeitos hemodinâmicos e renais determinados pela injeção de doses elevadas de clonidina no espaço peridural do cão. MÉTODO: Vinte animais anestesiados com tiopental sódico e fentanil foram distribuídos aleatoriamente e de forma duplamente encoberta em dois grupos: Grupo 1 ou placebo (n = 10), que recebeu 0,2 mL.kg-1 de solução fisiológica, e Grupo 2 ou clonidina (n = 10), que recebeu 0,2 mL.kg-1 de uma solução contendo 50 µg.mL-1 de clonidina, no espaço peridural. Foram avaliados os seguintes parâmetros hemodinâmicos: freqüência cardíaca (FC): bat.min-1; pressão arterial média (PAM): mmHg; pressão da artéria pulmonar ocluida (PAOP): mmHg; débito cardíaco (DC): L.min-1; volume sistólico (VS): mL; também, os seguintes parâmetros da função renal foram avaliados: fluxo sangüíneo renal (FSR): mL.min-1; resistência vascular renal (RVR): mmHg.mL-1.min; volume urinário minuto (VUM): mL.min-1; depuração de creatinina (D Cr): mL.min-1; depuração de para-aminohipurato (D PAH): mL.min-1; fração de filtração (FF); depuração de sódio (D Na): mL.min-1; depuração de potássio (D K): mL.min-1; excreção fracionária de sódio (EF Na): %; excreção urinária de sódio (U NaV): µEq.min-1; excreção urinária de potássio (U K V): µEq.min-1. O experimento consistiu em três momentos de 20 minutos cada. Os dados foram coletados aos 10 minutos de cada momento e a diurese, no início e no final de cada momento. Ao término de M1, a clonidina ou a solução fisiológica foi administrada no espaço peridural. Após período de 20 minutos iniciou-se M2 e, em seguida, M3. RESULTADOS: A clonidina na dose de 10 µg.kg-1 no espaço peridural do cão promoveu alterações significativas, com diminuições da freqüência cardíaca e do débito cardíaco e aumento da relação depuração de para-aminohipurato de sódio/débito cardíaco. CONCLUSÕES: Nas condições realizadas e nas doses empregadas, pode-se concluir que a clonidina não promoveu alteração da função renal, mas diminuiu valores hemodinâmicos (freqüência e débito cardíaco).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective To assess cardiopulmonary and analgesic effects after administration of ropivacaine into the caudal epidural space of cattle.Study design Prospective, single-dose trial.Animals Eight healthy mixed breed cows aged 8 +/- 5 years and weighing 507 +/- 112 kg.Methods Caudal epidural anesthesia was produced in cows with 0.75% ropivacaine (0.11 mg kg(-1)). Onset time, duration and cranial spread of analgesia were recorded. Heart rate (HR), respiratory rate (f(R)), rectal temperature (RT), and mean arterial blood pressure (MAP) were measured prior to epidural administration (T-0) and at 15, 30, 60, 120, 180 and 240 minutes after epidural administration (T-15, T-30, T-60, T-120, T-180 and T-240). Arterial blood acid-base balance (pH, standard bicarbonate and base excess), gas tension (PaO2, PaCO2, SaO(2)) and electrolytes (Na+, K+, iCa(2+), Cl-) were recorded at T-0, T-30, T-60, T-120, T-180 and T-240. Ataxia was evaluated at T-0, T-30, T-60, T-120, T-180 and T-240 and at 1 hour intervals thereafter until analgesia was no longer present in each animal.Results Epidurally administered ropivacaine induced variable analgesia extending bilaterally from the coccyx to S3. Time to onset of analgesia and mean duration in the perineal area were 15 +/- 4 and 359 +/- 90 minutes, respectively. Respiratory rate and RT increased from T-120 to T-240 when compared to the value at T-0. Ionized calcium and chloride concentrations increased at T-180 and T-240 when compared to T-0. The other variables were not significantly different from baseline values (p > 0.05). Four animals were mildly ataxic.Conclusion and clinical relevance Ropivacaine (0.75%, 0.11 mg kg(-1)) can be administered by caudal epidural injection to produce prolonged bilateral perineal analgesia with minimal ataxia and cardiopulmonary changes in standing cattle.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: The loss of resistance to air to identify the epidural space is widely used. However, the accidental perforation of the dura mater is one of the possible complications of this procedure, with an estimated incidence between 1% and 2%. The objective of this report was to describe the case of a patient with intraventricular pneumocephalus after the accidental perforation of the dura mater using the loss of resistance with air technique. CASE REPORT: Female patient, 26 years old, 75 kg, 1.67 m, physical status ASA I, with a 38-week pregnancy, was referred to the obstetric service for a cesarean section. Venipuncture was performed after placement of the monitoring. The patient was placed in a sitting position for administration of the epidural anesthesia. During the identification of the epidural space with the loss of resistance with air technique, an accidental perforation of the dura mater was diagnosed by observing free flow of CSF through the needle. The technique was modified to epidural anesthesia and anesthetics were administered by the needle placed in the subarachnoid space. In the first 24 hours, the patient developed headache and she was treated with caffeine, dypirone, hydration, hydrocortisone, and bed rest; despite those measures, the patient's symptoms worsened and evolved to headache in decubitus. A CT scan of the head showed the presence of pneumocephalus. After evaluation by a specialist, the patient remained under observation, with progressive improvement of the symptoms and was discharged from the hospital in the fifth day, without complications. CONCLUSIONS: Pneumocephalus after accidental perforation of the dura mater presented headache with the characteristics of headache secondary to loss of CSF, but with spontaneous resolution after the air was absorbed. Invasive measures, such as epidural blood patch, were not necessary. © Sociedade Brasileira de Anestesiologia, 2006.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cell therapy has frequently been reported as a possible treatment for spinal trauma in humans and animals; however, without pharmacologically curative action on damage from the primary lesion. In this study, we evaluated the effect of administering human adipose-derived stem cells (hADSC) in rats after spinal cord injury. The hADSC were used between the third and fifth passages and a proportion of cells were transduced for screening in vivo after transplantation. Spinal cord injury was induced with a Fogarty catheter no. 3 inserted into the epidural space with a cuff located at T8 and filled with 80 mu L saline for 5 min. The control group A (n = 12) received culture medium (50 mu L) and group B (n = 12) received hADSC (1.2 x 10(6)) at 7 and 14 days post-injury, in the tail vein. Emptying of the bladder by massage was performed daily for 3 months. Evaluation of functional motor activity was performed daily until 3 months post-injury using the Basso-Beattie-Bresnahan scale. Subsequently, the animals were euthanized and histological analysis of the urinary bladder and spinal cord was performed. Bioluminescence analysis revealed hADSC at the application site and lungs. There was improvement of urinary bladder function in 83.3% animals in group B and 16.66% animals in group A. The analysis of functional motor activity and histology of the spinal cord and urinary bladder demonstrated no significant difference between groups A and B. The results indicate that transplanted hADSC improved urinary function via a telecrine mechanism, namely action at a distance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: A peridural (AP) e a técnica de duplo bloqueio (DB) são utilizadas em analgesia para o trabalho de parto. Este estudo comparou os efeitos na mãe e no feto de ambas as técnicas em analgesia e anestesia para o parto. MÉTODOS: Quarenta parturientes ASA I e II receberam por via peridural 15 ml de ropivacaína a 0,125% (grupo AP) e 5 µg de sufentanil com 2,5 mg bupivacaína por via subaracnóidea (grupo DB). Foram avaliados: intensidade de dor, altura do bloqueio sensitivo, tempo de latência, bloqueio motor, duração da analgesia de parto, tempo para a resolução do parto, hipotensão materna e presença de prurido. Os recém-nascidos foram avaliados pelo índice de Apgar e escore da capacidade adaptativa e neurológica (ECAN), método de Amiel-Tison. RESULTADOS: Não houve diferenças significativas entre os grupos na intensidade da dor, no tempo de latência, no nível do bloqueio sensitivo e no índice de Apgar. O bloqueio motor, a duração da analgesia e o tempo para resolução do parto foram maiores no grupo DB, do qual sete parturientes apresentaram prurido leve. ECAN foi maior no grupo AP após meia hora, duas horas e 24 horas. Noventa e cinco por cento dos recém-nascidos do grupo AP e 60% do grupo DB foram considerados neurologicamente vigorosos ao exame de 24 horas. CONCLUSÃO: As duas técnicas mostraram-se eficazes para analgesia do trabalho de parto. As parturientes do grupo DB apresentaram prurido e trabalho de parto mais prolongado. Recém-nascidos de mães que receberam analgesia de parto via peridural apresentaram melhor ECAN.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this research, the epidural anesthesia technique in nulliparous and non non-nulliparous submitted to ovarysalpingohysterectomy was studied. These are rodents belonging to the Missina Palmeira Zancaner municipal zoo of catanduva in São Paulo. The tranquilization was achieved using azaperone (4mg/kg) and meperidine (4mg/kg) followed by injection of cetamine (20mg/kg) and xylazine (0.4mg/kg), intramuscularly from the same syringe. Subsequently, lidocaine (5mg/kg) was injected into the lumbosacral space. The time of latency of the anesthesic association (4.0[plus or minus]1.51min), time of latency of epidural lidocaine (6.87[plus or minus]2.35min) and time of analgesia (115.0[plus or minus]12.49min) were analyzed, in addition to rectal temperature, which decreased 2.12[plus or minus]0.86[degree]C on average from the beginning of the anesthesia to the end of its effective time. All animals recovered satisfactorily without presenting signs of excitation or complications due to the epidural tecnique. It was concluded that the balanced anesthesia tecnique provided adequate analgesia during a time considered sufficient for several procedures, by means of low doses of xylazine and ketamine.